Modular Fire Protection System
  • Part Number: Consult with Alpha for PN
  • Product Line: Battery Accessories
AFP 10 Series UPS

Product Highlights

  • >92% energy efficiency
  • Operates at optimal efficiency at 50-100% of the load
  • All modules are hot swappable
  • Scalable architecture and modular design
  • Unique Twin Sine Inverter (TSI) technology filters out harmonics on the AC input and provides AC power filtering and conditioning
  • Available N+1 redundancy (5kVA and 7.5kVA); only one module is required for redundancy, rather than an entire system.
  • Description

    The AFP 10 is a continuous duty, single-phase, double-conversion, solid-state uninterruptible power supply designed specifically for fire protection alarm/signal systems. Its operational level of greater than 92% power efficiency results in less power usage than typical UPS systems. With an optimal system efficiency at 50 to 100% of load, additional inverter and/or rectifier modules may be added to the system with no negative impact on system efficiency.

    Rectifiers charge the batteries only when necessary and the charging capacity of the system rectifiers is proportional to battery capacity. This optimizes battery recharge time and minimizes the number of rectifiers necessary to support the batteries.

    The unique Twin Sine Inverter (TSI) modules provide harmonic filtering and conditioning of the AC input and AC output power. Compensation for fluctuations in input power combined with full sine wave output eliminates the need to draw power from the DC supply and extends the operational life of the DC system.

    All modules are hot swappable, each module can disconnect itself from the system in event of failure, and each module can operate as part of a bypass of AC power to the load. Additionally, the scalable architecture of the AFP 10 allows flexibility for easy future system expansion.


    • System Components
      Cordex™ switched mode battery charger/rectifier
      Pulse-Width Modulated (PWM) modular Inverter with built in modular static switch and internal AC-DC rectifier
      Manual make before break (MBB) bypass switch
      Microprocessor Controlled Logic and Control Panel for DC section and AC section
      Input and Output Circuit Breakers
      Nominal Specifications
      UPS Input
      Input Voltage: 120Vac
      Input Voltage Requirement: Phase, 2 Wire + Ground
      Voltage Variation: +10% to -15%
      Input Current: 12A Max @ 90-135Vac per each rectifier module,
        21A Max @ 120Vac per each inverter module
      Rated Frequency: 50/60 Hz
      Frequency Range: 45 - 66 Hz
      Power Factor: > 0.98 at nominal conditions and 50-100% load
      Start Up Delay: Programmable up to 120 seconds to enable stagger-start of multiple rectifiers and to minimize the effect on a supply source
      Soft start: User adjustable to at least 5 seconds (not including start-up delay time) and is determined by output current limit ramp-up
      Inrush Current: ≤ full load steady state current of the rectifier within rated limits
      Input Current THD: 92% at nominal conditions and 50-100% load
       
      UPS Output
      Rated Voltage: 120Vac
      Output Voltage Requirements: 1 Phase, 2 Wire + Ground
      Output Capacity: 5.0/7.5/10.0 kVA
      Rated Load Power Factor: 0.8 lagging
      Voltage Regulation: +/- 2%
      Frequency: 50-60Hz.
      Frequency Accuracy: 0.03%
      Frequency Regulation: +/- 0.01% free running
      Transient Voltage Recovery: 0.4ms maximum to within 2% of nominal
      Overload Cap. (on inverter): 110% continuously, 150% for 5 sec.
      Overload Cap. (on bypass): 1000% for 10ms, 125% for 10 min.
      Crest Factor: 3.5
      Harmonic Voltage Distortion: 1.5% THD maximum, 1% maximum for any single harmonic (linear load)
      MTBF: 230,000 hrs.
      Efficiency: >90%
       
      Mechanical Specifications
      Enclosure dimensions HxWxD (in/mm): 52 x 26 x 24 / 1320 x 660 x610
      Weight (lb/kg), configuration-dependant: 310 to 370 / 140 to 168
       
      Environmental Specifications
       
      Operating Temperature:
      UPS: 32° to 104°F (0° to 40°C)
      Battery: 68° to 77°F (20° to 25°C)
       
      Storage Temperature:
      UPS: -4° to 140°F (-20° to 60°C)
      Battery: Prolonged storage above 104°F (40°C) causes rapid battery degradation
      Relative Humidity: 90% (non-condensing)
      Audible Noise: 65 dBA @1m distance
      Agency Compliance: ANSI C62.41 (IEEE 587)
        UL 1481
        National Electrical Code (NFPA-70)
        NEMA PE 1-2003
        OSHA